A double glazed unit, or IGU, is two panes bonded to a spacer bar with a sealed cavity between them. When the edge seal fails, moisture enters the cavity and the unit mists. The unit is replaced; the frame usually stays.

Free measured survey · fixed written quotation

Double glazed unit replacement — technical detail
Double glazed unit replacement — technical detail
  • Free measured site survey
  • Fixed written quotation
  • Mainland UK coverage
  • Commercial specialists only
  • 24-hour emergency response

Misting means the seal has failed — it cannot be fixed

Once moisture is inside the cavity, the desiccant in the spacer bar is saturated and the unit is finished. Drilling and 'defogging' clears the visible mist for a while but leaves an unsealed cavity that will mist again and has lost its gas fill and much of its thermal performance.

The honest answer is replacement of the unit. The frames, hardware and seals normally stay, which is why this is a fraction of the cost of new windows.

Replace the unit or replace the window?

If the frames are sound, square and the hardware works, replacing the units is far better value — typically a quarter to a third of the cost of full replacement, with no making good and no disruption to the fabric.

Replace the whole window when the frames are rotten or distorted, when the thermal break has failed, when the opening lights no longer seal, or when the required U-value cannot be reached with a glass change alone.

Upgrade while the frame is open

A unit swap is the cheapest opportunity you will get to change the glass performance. For a modest uplift you can move to acoustic laminate on a road-facing elevation, solar control on a south face that overheats, or toughened where a Part K critical location was previously glazed in annealed float.

We survey for all three as a matter of course and flag them rather than quietly replacing like for like.

Specification

Specification
StandardBS EN 1279 (insulating glass units)
Typical build-up4mm-16mm-4mm, overall 24mm or 28mm
Cavity fillArgon — around 0.1 W/m²K better than air
SpacerWarm edge composite spacer, replacing older aluminium
CoatingSoft-coat low-emissivity on the cavity face
Centre-pane U-value1.1–1.4 W/m²K typical for a modern replacement unit
OptionsToughened, laminated, acoustic, solar control, integral blinds
Typical lead time5–10 working days for standard units

Indicative rate

£110 – £260
per m² · excludes VAT

Supply and install into existing sound framing at accessible level. Toughened, laminated, acoustic and solar control units, and any work above ground level, are additional.

Indicative range for budgeting — not a quotation

Build a budget figure Book a free survey

Double glazed unit replacement — common questions

How long do sealed units last?
Twenty to thirty years is typical for a well-made unit in a well-drained frame. Units fail much sooner where drainage is blocked and the unit sits in standing water, or where they are in a very exposed south-facing elevation with heavy thermal cycling.
Can misted units be repaired instead of replaced?
Drilling and drying is offered by some firms. It clears the appearance temporarily but the cavity is no longer sealed, the argon has gone and the misting returns. We do not offer it because it is not a repair.
Do I have to replace all the units at once?
No, but consider it on a visible elevation. New units with modern soft coatings can look slightly different against thirty-year-old glass, and a phased replacement means repeat access costs on anything above ground level.
Will new units cut my heating bills?
Modestly, and mostly on older stock. Moving from a failed unit to a modern argon-filled low-e unit can roughly halve the heat loss through that glass. Where the existing units are already low-e, the gain is small and comfort is the better reason.
How quickly can a broken unit be replaced?
We make safe immediately — usually the same day for a commercial premises. The replacement unit itself is normally five to ten working days, longer for toughened, laminated or specialist glass.

Tell us what the building needs

Free measured survey, fixed written quotation, and a straight answer about what is and is not worth doing. Mainland UK, commercial work only.