Sector
Glazing for offices and workplaces
Office glazing splits into two very different jobs: the facade, which is a construction project with weather and programme risk, and the internal fit-out, which is an occupied-building exercise measured in noise, dust and disruption.
Free survey · phased around your operation
Tell us about the building
Same working day response.
- Free measured site survey
- Fixed written quotation
- Mainland UK coverage
- Commercial specialists only
- 24-hour emergency response
What matters most on this kind of building
Acoustic separation that actually works
Meeting rooms and HR spaces need double glazed partitions taken to slab or with a properly detailed head barrier. A 45dB screen under an open ceiling void performs like a 30dB one.
Working around occupation
Facade replacement runs floor by floor behind temporary screens; partitions go in with low noise during the day and slab-fixing out of hours.
Part L on refurbishment
Where more than a set proportion of the facade is replaced, the thermal element usually has to be upgraded. That is a whole-window calculation, not a glass one.
Solar gain on south and west faces
Glare and afternoon overheating drive more workplace complaints than winter cold. Solar control glass is far cheaper than adding cooling.
Services
What we are usually asked for
Curtain walling
Curtain walling is a non-loadbearing aluminium and glass facade hung off the structural frame of a building.
Glass partitions
A glass partition is a non-loadbearing internal screen that divides a floor plate without blocking light.
Commercial aluminium windows and doors
Commercial aluminium windows and doors are thermally broken framed units built for heavy use — far higher cycle ratings, wider spans and stronger hardware than residential equivalents, with a polyamide break separating inner and outer frame.
Double glazed unit replacement
A double glazed unit, or IGU, is two panes bonded to a spacer bar with a sealed cavity between them.
Automatic doors
An automatic door is a powered entrance — sliding, swing or telescopic — controlled by activation and safety sensors and governed by BS EN 16005.
Offices and workplace — common questions
Can office glazing be replaced without decanting the floor?
What acoustic rating does a meeting room need?
Does replacing office windows trigger a Part L upgrade?
Tell us what the building needs
Free measured survey, fixed written quotation, and a straight answer about what is and is not worth doing. Mainland UK, commercial work only.